Login

Lost your password?
Don't have an account? Sign Up

Coil Tubing Annular Frac

Tension/Closed; Compression/Open

Hydro-Mechanical Perforator

Pump above 200 L/min closes valve

For lower annular isolation

For lower annular isolation

to allow unloader to flow thru

OPERATION

Coil Tubing Annular Frac
The Gator Perforator with a compression set packer can be used to perforate and annular frac a wellbore in a single trip. The combination of perforating and stimulating allows for a more pinpoint frac to ensure maximum returns from each zone. This system will accommodate acid or proppant. The combination of a single trip and Coil tubing conveyed allows for a quick operation. This ensure that the client puts the well back on to production as soon as possible.

• Run in hole to desired depth (Packer in "run in" position; last motion up to close the ULS Sub)
• Activate Gator by flowing at 200 L/min to close VCV & Pressure up to 2000 psi; watch for cut signature or drop in tubing pressure to indicate successful cut.
• Pull up 1 meter to retract blades
• Position the Blast Joint over the perforations and set Auto J Packer with a compression stroke. This will also open the ULS Sub
• Ready for frac ops
• Flow thru the CT at 50 L/min. This will exit out the VCV & ULS and allow positive flow to keep fluid moving out the coil. It will also allow for the pressure to equalize in the CT to keep it from collapsing.
• Pump frac down the annulus of the coil.
• Once frac is pumped away, follow with an overflush.
• Pull up to next zone and repeat until all stages are complete.

PDF REQUEST FORM

Please provide your details below, and a brief description of the info you would like, and within 72 hours a Lee Energy Systems Team member will be in contact to provide you access to our Catalogue

Contact Information

JOB REQUEST FORM

Please provide your details below and we will contact you within 72 hours

Contact Information
Well Information
Job Type